LT SERIES UPS SYSTEM
Intelligent Line Interactive Sinewave - Long backup
700 / 1000 / 1500 / 2000VA

The LT Series UPS is an advanced true sinewave line-interactive UPS system which is designed to prevent any spike, sags and blackout from reaching your sensitive equipment; ranging from computers and tele-communications systems to computerised instruments. The LT Range has a more powerful battery charger and is therefore suitable for larger battery banks, providing longer back-up times.

Under normal power conditions the UPS filters out all small fluctuations. During power failure, the unit employs its internal maintenance-free batteries to supply back-up power without any interruption. The UPS is equipped with many features, which make both your equipment and UPS more reliable.

  • Line-interactive Charger and Bi-directional Inverter - the highest performance for protection from frequent brown outs;
  • Microprocessor Based Design - digital UPS control and automatic 50/60Hz frequency select;
  • Pure Sine Waveform Output - the cleanest, most compatible AC output for computer systems;
  • Automatic Voltage Regulation (AVR) - provides stable power and true brownout and over voltage correction;
  • Intelligent Boost and Buck - additional protection for an extended AC voltage window;
  • Battery Diagnosis - self testing for limiting operation, assuring quality and longer life of battery;
  • RS232 Communication - Compatible for sophisticated monitoring software.

LT UPS

TECHNICAL SPECIFICATIONS

 

MODEL
 

LT700

LT1000

LT1500

LT2000

Output VA Rating 700VA 1000VA 1500VA 2000VA
Wave form Pure sinewave
RMS Power 470W 670W 1000W 1200W
Current 230V 3.0A 4.3A 6.5A 8.7A
Voltage regulation 230V + 11.3% / - 15.2% (under line mode)
230V ± 6% (under backup mode)
Frequency regulation 45Hz to 65Hz (under line mode)
50Hz or 60Hz ± 0.Hz (under backup mode)
Efficiency AC to AC > 95%
Total harmonic distortion < 5% at full non-linear
< 10% when battery low
Overload capacity > 110% of full load with 10 sec. delay
> 150% of full load with 1 sec. delay
Input Phase Single Phase with ground
Voltage 171VAC-278VAC
Frequency 45 / 65Hz Auto Select
Current Nominal 3.8A 6.1A 7.8A 10.6A
Current Maximum 4.4A 6.9A 9.1A 12.2A
Power Factor Under full load (p.f.=0.67/0.6) nominal input voltage
Under full load (p.f.=0.67/0.6) low input voltage and max. charging current
Battery DC Voltage Minimum 20 VDC 30 VDC 40 VDC 50 VDC
DC Voltage Nominal 24 VDC 36 VDC 48 VDC 60 VDC
DC Voltage Maximum 27.5 VDC 41.5 VDC 55 VDC 69 VDC
Type 12V / 7AH Lead acid maintenance free
No of batteries 2 pcs 3 pcs 4 pcs 5 pcs
Full charge voltage 27.5 VDC 41.5 VDC 55 VDC 69 VDC
Charge current *5.0A - Caution : suggest charging current for more than 28Ah battery capacity
Backup time Several min. to several hours depending on capacity of external battery
Recharge Time 8 hours dependant on capacity of external battery
Audible Noise
  
< 45 dBA at one meter
Transfer Switch Type Relay
Transfer time Bypass to inverter, inverter to bypass : 5 ms (typical)
Transfer criteria Line abnormal
Interface Signal Signal Type Photo-coupled LAN signal and isolated RS232
Connector Type DB9 female connector
Signal Line failure, low battery
Remote shutdown UPS can be shutdown by external signal
Remote Control   Programmable shutdown-reboot function and show out UPS status with "RUPS/UPSilon2000" software
Protection   Electronic overload and short circuit protection
Automatic shutdown at low battery voltage
Control   On/Off Switch
Test/Alarm-reset switch
Line input circuit breaker or fuse
Indicators Status LINE(G), ON BAT.(Y), ON AVR(Y), BAT. WEAK/LOW BAT.(R), FAULT/OVERLOAD(R)
Load Level 3 Green LEDs and Fault/OVERLOAD (R)
Audible Alarm Battery discharge From 10 sec. 2 beeps to 2 sec. 2 beeps to signify battery level
Every sec. 2 beeps when battery low
Overload Two beeps every second
Fault Beeps continuously
Cooling   Air convection Forced air cooling with fan
Mechanical Dimensions (WxHxD)(mm) 120x160x360 160x200x450 160x200x450 160x200x450
Weight G.W. (kg) No batteries 22.9 / 24.1 13.4 / 14.6 16.9 / 18.1 16.9 / 18.1
Environment Temperature 00C - 400C
Humidity 0-95% Non-Condensing
Altitude Less than 3000 meters above sea level
Storage Temperature - 150C to 400C
Approvals Safety CE / TUV, C-Tick
EMC EN50091-2, CE
LVD EN50091-1
Optional   SNMP External Card
 

 

LONG BACKUP UPS SYSTEMS

Long back - up UPS- LH & LT